Tissue Paper Plumpness Tester
Categories:Tissue Paper Tester
Name:Tissue Paper Plumpness Tester
Model:PN-PLTF
PN-PLTF tissue paper plumpness tester is a kind of measuring the plumpness of various household papers developed by our company according to customer requirements mainly including soft pumping box pumping paper handkerchiefs coreless toilet pape
Download:
Video:Click Play
Introduction
The instrument is a mechatronics product. It adopts modern mechanical design concepts and ergonomic design principles, and is carefully and reasonably designed with advanced high-speed ARM processors. It is a novel design, easy to use, excellent performance and elegant New generation of Plumpness tester.The device adopts a vertical structure. The smallest test sample is a small handkerchief paper bag. The test sample space is 200mm in depth (forward and backward direction), 450mm in height, 400mm in width, and the pressure can be set arbitrarily within 100N.
Technical parameter
Power supply: AC 100~240V±10% 2A 50/60HZ
Accuracy: ±1%
Indication variation: <1%
Resolution:0.1N
Measuring range: (0.5-100)mN
Deformation error: ≤±1mm
Working stroke: (5~450)mm
Platen size: 200X400mm
Measuring rod size: Length 15cm dia. 15mm
Testing speed: ( 5~500)mm/min
Return speed:( 5~500)mm/min
Display:: 5” touch screen
Printing output: Built-in thermo-printer
Output: RS232/USB(optional)
Working environment: room temperature (20±10)℃ relative humidity: <85%
Dimension: 470 mm×450mm×920mm
Weight: 45kg.
Accuracy: ±1%
Indication variation: <1%
Resolution:0.1N
Measuring range: (0.5-100)mN
Deformation error: ≤±1mm
Working stroke: (5~450)mm
Platen size: 200X400mm
Measuring rod size: Length 15cm dia. 15mm
Testing speed: ( 5~500)mm/min
Return speed:( 5~500)mm/min
Display:: 5” touch screen
Printing output: Built-in thermo-printer
Output: RS232/USB(optional)
Working environment: room temperature (20±10)℃ relative humidity: <85%
Dimension: 470 mm×450mm×920mm
Weight: 45kg.
Product features
Pressure can be set;
The residence time after pressurization can be set less than 10s;
Intelligent design of stroke protection overload protection over-range alarm function and automatic cleaning to ensure the user's operation safety;
Data upload data.
The residence time after pressurization can be set less than 10s;
Intelligent design of stroke protection overload protection over-range alarm function and automatic cleaning to ensure the user's operation safety;
Data upload data.
National standard
NO
Relevant information
NO